Skip to Content
Kenall Manufacturing - Homepage
Main Content

METSR

Millenium Metrex Exit & Emergency

METSR Main Image
METSR Main Image
Model #: METSR
Features:
  • Semi-recessed wall mount – Single Face
  • Indirect Red or Green LED
  • Internal Battery Backup System
  • 20-gauge cold rolled steel housing
  • Self diagnostic testing features
Application(s):Parks and Recreation
Packaging and Staging
Multifamily Housing
Cafeterias
Restrooms
Stairwells
Foyers and Lobbies
Corridors
Gymnasiums and Multipurpose Rooms
Exit
Lamp Type(s):LED
Listings:       
Specifications are subject to change without notice. Please consult your Kenall Customer Service for help with special requests at (800) 4 Kenall.

Technical Specifications

Electrical624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Remote Exit Ready – can power one Kenall METSS Satellite Exit.
FastenersHardened security screws as specified – see ordering information.
FinishTGIC polyester powder coat – 5-stage pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%. See Options for black exterior.
FrameOne-piece die-formed prime grade 16-gauge material as specified – see Ordering Information. Corners continuously seam welded and smooth with no post grinding (TIG).
Housing20-gauge CRS. Hole-free one-piece seam welded construction.
LegendLegend illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, punched, formed and painted sheet metal stencil and field selectable chevron inserts.
LensExternal panel .188 inch thick clear polycarbonate.
ListingsUL and CUL listed for Wet Location. UL certified IP65 in compliance with IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements.
OptionsSealed nickel-cadmium Emergency Battery Pack (EL) with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Provides 120 minutes of emergency operation. Emergency Battery Pack (EL) suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CEL) suitable for -45°C to 45°C (-49°F to 113°F). (When used with a Kenall METSS, this fixture provides 90 minutes of emergency operation.)

This product complies with the Buy American Act: manufactured in the United States with more than 50% of the component cost of US origin.