Doorframe | Heavy duty extruded aluminum with clear satin anodized finish. Doorframe supported to housing with aircraft cables (IB-AC) to provide NSF2 listing, or an optional continuous hinged doorframe (IB-HD). Select in ordering options below. Phillips-head stainless steel fasteners secure door to housing- 8 with IB-AC and 2 with IBHD. Extruded closed cell gasket seals lens frame to housing. |
---|
Driver | 120-277VAC, 50/60Hz electrical input (PF ≥ 0.9, THD < 20%). Minimum 85% electrical efficiency. AMBIENT: Serviceable, constant-current multi-channel programmable driver with dual analog (0-10V) control inputs for intensity and CCT. EXAM: Serviceable constant-current programmable driver. Dimming protocol matches tunable white circuit selection: 0-10V dimming with 1-100% range and dim-to-dark capabilities or DALI with 1-100% range and dim-to-dark capability. |
---|
Housing | FLANGE AND GRID: 20-gauge CRS one-piece seam welded construction. SURFACE: 18-gauge CRS one-piece seam welded construction. White TGIC polyester powder coast – 5-stage pre-treatment. Salt spray test 1,000 hours. Reflectance 92%. (See options for Antimicrobial Finish). Housing Flanges – 18-gauge CRS . |
---|
Installation | Surface Mount: Four .312" diameter holes. Grid Mount: Designed for 1" and 1.5" grid. (Housing includes hanging brackets to secure housing with wire to super structure). Flange Mount: Yoke mounting hardware & brackets included. Install Frame and Plaster Frames both positively locates yoke brackets within ceiling opening assures alignment of fixture. Install frame has no need for drywall backing. Backing is supplied on the frame brackets. |
---|
Lamp Shielding | Ambient center shield is frosted linear high impact prismatic acrylic, flanked on both sides with a perforated aluminum basket with pearlescent acrylic diffuser. Metal parts are white TGIF polyester powder coat finish. |
---|
LED Module | AMBIENT: Serviceable tunable-white, mid-power LED array provides 2700K through 6500K CCT range with a two-point path. 3-step MacAdam variation allowance on each CCT. Minimum 82 CRI standard (R9 >20) with optional minimum 92 CRI (R9 >50). EXAM: Serviceable mid-power LED array. See Ordering Information for CCT options. 3-step MacAdam variation allowance. 82 CRI minimum. |
---|
Lens | Supplied with IB-AC or IB-HD Options. .125" clear high impact acrylic. Sealed to extrude aluminum frame with a vinyl gasket. |
---|
Listings | UL and CUL Listed for Wet Location and UL certified IP65 per IEC 60598. NSF2 Splash/Non-Food Zone (IB-AC only). |
---|
Optics | Outer lens constructed of 0.125” clear impact-resistant acrylic and sealed to doorframe with vinyl gasketing. Inner basket constructed with extruded frost acrylic over central Ambient function lamping, flanked on both sides with diffused painted aluminum perforated shields over Exam function lamping. |
---|
Patent | U.S. Patent No. D562,767 on Low Voltage Controller (LVC) option. |
---|
Warranty | Limited five (5) year warranty. |
---|