Construction | Extruded aluminum heat sink. White endcaps. Extruded frosted acrylic lens. |
---|
Electrical | Mid-power white and 405nm Indigo LED array. Available 4300K color temperatures with 3-step MacAdam variation allowance. Minimum 80 CRI standard. 120-277VAC electrical input with serviceable high power factor electronic, constant-current drivers (>0.95 PF). Standard 0-10V dimming with 1-100% range. 400µA maximum source current. EMC meets or exceeds FCC CFR Part 15 Class A. RoHS complaint. Minimum operating temperature -40°C. Single, white disinfection mode. |
---|
Installation | These lamps are only to be installed in fixtures with a maximum ambient temperature of 25°C. 2' luminaire lamp system consist of (4) lamps and (1) driver. 4' luminaire lamp system consist of (2) lamps and (1) driver. Existing T8 ballast must be disconnected and removed from luminaire. See Wiring Diagrams and Installation Instructions for additional details. Labeling required for retrofit notification included. |
---|
Listings | Tested in accordance with UL1598C by Intertek, classified for use in Kenall Wet Location Listed and IP-rated fluorescent luminaires. |
---|
Photometrics | Photometry tested to the IESNA LM-79-08 standard by an ILAC/ISO17025 accredited laboratory. For additional photometric data, please go to www.kenall.com. |
---|
Warranty | Five (5) year warranty. |
---|